HN Series Emergency Stop Switches
Unique “Safe Break Action”
IP65 Degree of Protection
Features & Benefits
- Safety lock mechanism
- Direct opening action mechanism
- Unibody. Finger-safe terminals
Type
Name
Downloads
HN Series Emergency Stop Switches Brochure
HW Series Emergency Stop Switches (Unibody)
Unique Safety Mechanism
IP65 Degree of Protection
Features & Benefits
- Finger-safe terminals. Ensure safety and wiring time.
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1, Annex K)
Type
Name
Downloads
HW Series Emergency Stop Switches Brochure
HW Series Emergency Stop Switches (with Removable Contact Block)
Unique Safety Mechanism
22 mm hole size with finger-safe structure
Features & Benefits
- Complete with finger-safe contact blocks. Ensure safety and wiring time.
- Safety lock mechanism (IEC 60947-5-5, 6.2).
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1).
Type
Name
Downloads
HW Series Emergency Stop Switches Brochure
SEMI Emergency OFF (EMO) Switches
Removable contact block with 16 mm/ 22 mm hole size
Features & Benefits
- Complete with finger-safe contact blocks. Ensure safety and wiring time.
- Safety lock mechanism (IEC 60947-5-5, 6.2).
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1).
Type
Name
Downloads
SEMI Emergency Off (EMO) Switches Brochure
Stop Switches
Wider variety with yellow button, white guard and nameplate
Unibody with IP65 degree of protection.
Features & Benefits
- According to SEMI S26-0308 Environmental, Health, and Safety Guideline for FPD Manufacturing Systems published in March 2008, the combination of a red button and yellow background cannot be used for switches that have only local or partial shutdown functions. IDEC’s yellow button switch, white switch guard, and nameplate can satisfy the requirement.
Type
Name
Downloads
Stop Switches Brochure
X6 Series Emergency Stop Switches (Unibody)
Smallest in its class
Third-generation emergency stop switch with Reverse Energy Structure
Features & Benefits
- Two button sizes: 30mm and 40mm
- Two button colors: Red for emergency stop switch and yellow for stop switch
- Two ways of resetting: Pulling and turning.
- UL, c-UL recognized, EN compliant.
- Safety lock mechanism (IEC 60947-5-5; 6.2)
- Direct opening action (IEC 60947-5-5; 5.2, IEC 60947-5-1)
- Degree of protection: IP65 (IEC60529)
Type
Name
Downloads
X6 Switches Emergency Stop Switches Brochure
XA Series Emergency Stop Switches (Unibody)
16 mm hole size with pushlock pull/ turn reset
Small, unibody emergency stop switches suitable for equipment with small mounting space.
Features & Benefits
- ø29mm and ø40mm mushroom operators
- Degree of protection IP65 and IP40 (IEC 60529)
- Dark red (Munsell 5R4/12) and bright red (Munsell 7.5R4.5/14) for operators of emergency stop switches, and yellow/gray for stop switch operators.
- Gold-plated crossbar contacts
- Push-to-lock, pull or turn-to-reset operator
- UL, c-UL recognized. EN compliant.
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1)
Type
Name
Downloads
XA Series Emergency Stop Switches (Unibody) Brochure
XA Series Emergency Stop Switches (with Removable Contact)
Safety lock mechanism with IP65 degree of protection
The world’s first 16 mm, 4-contact emergency stop switch.
Features & Benefits
- The depth behind the panel is only 27.9 mm for 1 to 4 con tacts, both on illuminated and non-illuminated.
- IDEC’s original “Safe break action” ensures that the contacts open when the contact block is detached from the operator.
- 1 to 4NC main contacts and 1NO monitor contact
- Push-to-lock, Pull or Turn-to-reset operator
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1)
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Degree of protection IP65 (IEC 60529)
- Two operator sizes: ø29 and ø40 mm
- Dark red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors are available for the operator of non illuminated emergency stop switches, and gray for stop switch operators.
- UL, c-UL recognized. EN compliant (IEC 60947-5-5, 5.2, IEC60947-5-1, 60529)
Type
Name
Downloads
XA Series Emergency Stop Switches (with Removable Contact Block ) Brochure
XN Series Emergency Stop Switches
30 mm 4 contact emergency stop switch
Pad lockable and flush bezel are available
Features & Benefits
- Padlockable, flush bezel, ø60mm jumbo mushroom, illuminated, LED push-on are available.
- IDEC’s original “Safe break action” and reverse energy structure ensure the highest level of safety.
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC60947-5-1)
Type
Name
Downloads
XN Series Emergency Stop Switches Brochure
XW Series Emergency Stop Switches
22 mm 4 contact emergency stop switch
IP65/IP20 Degree of Protection
Features & Benefits
- The depth behind the panel is only 37.1mm for 1 to 4 contacts (screw terminal style 48.7mm with terminal cover).
- The same depth behind the panel for illuminated and non-illuminated switches.
- IDEC’s original “Safe break action” ensures that the contacts open when the contact block is detached from the operator.
- 1 to 4NC main contacts and 1 or 2NO monitor contact
- Push-to-lock, Pull or Turn-to-reset operator
- Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K)
- Safety lock mechanism (IEC60947-5-5, 6.2)
- Degree of protection IP65 (IEC60529)
- Screw terminal style is finger-safe (IP20).
- Two operator sizes: ø40 and ø60mm
- Dark red (Munsell 5R4/12) or bright red (Munsell 7.5R4.5/14) colors are available for the non-illuminated operator.
- Push-ON illumination available (operator size: ø60)
- Connector style available to reduce wiring time and wiring mistakes.
- UL c-UL listed. EN compliant.
Type
Name
Downloads
XW Series Emergency Stop Switches Brochure
XW Series Emergency Stop Switches (Mechanical Indicator)
High level of safety with safe break action
Mechanical indicator on the operator body shows the contact status
Features & Benefits
- IDEC’s original “Safe Break Action” and “Reverse Energy Structure” ensure the safety of operator and system, when the switch is damaged due to excessive shocks.
- The mechanical indicator on the operator body shows the normal/latched status (green: normal). Reduces maintenance work and improves operation efficiency.
- Illuminated model also available (same size as non-illuminated)
- The depth behind the panel is only 46.4mm (w/terminal cover).
- 1 to 4NC main contacts and 1 or 2NO monitor contact
- Push-to-lock, Pull or Turn-to-reset operator
- Direct opening action mechanism (IEC 60947-5-5, 5.2, IEC 60947-5-1, Annex K)
- Safety lock mechanism (IEC 60947-5-5, 6.2)
- Degree of protection: IP65 (IEC 60529)
- Durable gold-plated contacts
- Finger-safe structure (IP20)
- UL, c-UL listed. EN compliant
- UL NISD category
Type
Name
Downloads
XW Series Emergency Stop Switches (Mechanical Indicator) Brochure
YW Series Emergency Stop Switches
Unique Safety Mechanism
22 mm hole size with IP65 degree of protection
Features & Benefits
- Space-saving, 10mm thick contact blocks. Removable operator.
- Compact and light-weight.
- Metal bezel, unibody pilot lights, and key selector switches available.
- Separate contact block makes installation and removal easy.
- IP65 (panel front) (IEC 60529)
Type
Name
Downloads
YW Series Emergency Stop Switches Brochure