HS1T Interlock Switches with Solenoid

Mechanical Indicator with IP67 degree of protection
Ideal for use on large doors and large equipment requiring strong locking force.
Features & Benefits
- Locking force of more than 5000N (40mm-wide slim model)
- Greatly downsized from IDEC’s HS1L interlock switches.
- Head rotating structure. Can be roated without removing the head.
- Prevents invalid operation. (On usual interlock switches, the NC contact closes when the head is removed)
- Energy efficient 200mA solenoid consumption
- Mechanical durability improved to 2,000,000 operations
- Spring clamp terminals wit side- conduit model
-
Lock status can be identified from the front Rear unlock mechanical indicator (First in the industry)
Type
Name
Downloads
HS1B/2B Interlock Switches

Machines stops when the door is opened
Direct opening mechanism with 2 actuator entry slots.
Features & Benefits
- When mounting the actuator on a movable door and the interlock switch on a machine, opening or closing status of the door can be detected.
- Contact parts degree of protection: IP67 (IEC 60529)
- NC contacts feature direct opening mechanism (IEC/EN 60947-5-1).
- Special actuator prevents defeating (ISO 14119, EN 1088)
- Detects entry to hazardous area when mounted on safety guards.
- Two actuator entry slots and three conduit ports are provided.
- HS1B: Rugged die-cast aluminium housing
- HS2B: Compact and lightweight plastic housing
Type
Name
Downloads
HS1C Interlock Switches with Solenoid

IP67 rated rugged die-cast aluminium housing
The guard door remains locked until the machine stops completely.
Features & Benefits
- With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.
- The door is unlocked by a solenoid lock-release signal from a PLC or another source after the machine has stopped, ensuring higher safety.
- In the event of power failure or for machine maintenance, the door can be unlocked using a special tool.
- Flexible installation: The actuator can be inserted into two directions.
- Select from four different circuit configurations.
Type
Name
Downloads
HS1C-K Interlock Switches with Solenoid and Hostage Key

Operator’s safety inside the hazardous area is ensured with the portable key
Hostage control for large system or machine applications is achieved.
Features & Benefits
- The door and key are locked during machine operation.
- The door is unlocked by removing the key, and the interruption of load circuit and control circuit are maintained.
- Ideal as a portable key for bringing into the hazardous area.
- 30 different numbers are available for key, so that neighboring switches cannot be operated by the same key.
- Flexible installation: The actuator can be inserted into two directions.
- IP67 rated rugged die-cast aluminum housing.
Type
Name
Downloads
HS1E Interlock Switches with Solenoid

3000N locking strength
Suitable for large and heavy doors.
Features & Benefits
- Same actuator as HS1E (actuator retention force 3000N)
- Six contacts in a compact housing (same size as HS1E)
- Same dimensions and mounting hole layouts as HS1E (Size: 35 × 104 × 129 mm)
- Door open, closed, and locked statuses can be monitored for various applications.
- Energy efficient new solenoid unit. 32% less solenoid current consumption compared with HS1E.
- Manual unlock key and LED indicator are standard.
- Manual unlock key allows for manual unlocking in the event of power failure or maintenance.
- Indicator has an independent circuit, and can be used for various purposes.
- Two locking mechanisms to choose from—spring lock (unlocked with energized solenoid) or solenoid lock (locked with energized solenoid).
- M3 terminal screws for wiring.
- Wide operating temperature range (–20 to +55°C).
HS5E Interlock Switches with Solenoid

Small safety switch with four poles and solenoid
Ideal for applications in tight spaces.
Features & Benefits
- Compact body. 35 × 40 × 146mm.
- Rear unlocking button for emergency escape available. Also available is the rear unlocking button kit.
- A variety of circuits—dual safety circuit and four-circuit independent outputs available.
- Gold-plated contacts.
- Spring lock and solenoid lock are available.
- The head orientation can be rotated, allowing 8 different actuator entries.
- A metal entry slot ensures high durability.
- An actuator with rubber bushings alleviates the impact of actuator entry into the slot.
- The actuator retention force is 1400N minimum (GS-ET-19).
- Integral cable design minimizes wiring, preventing wiring mistakes.
- LED indicator indicates the solenoid status.
- Double insulation structure.
- Automatically locks the actuator without power applied to the solenoid.
- After the machine stops, unlocking is completed by the solenoid, providing high safety features.
- Manual unlocking is possible in the event of power failure or maintenance.
- The actuator is locked when energized.
- The actuator is unlocked when de-energized.
- Flexible locking function can be achieved for an application where locking is not required and sudden stopping of machine must be prevented.
Type
Name
Downloads
HS5E-K Interlock Switches with Key

Head removal detection with IP65 degree of protection
New interlock switches that can be locked and unlocked with a key.
Features & Benefits
- Head removal detection circuitry.
- High-security pin tumbler key is used. Sixteen types of key numbers are available.
- Available with rear unlocking button for emergency escape.
- Accessory available for aluminum frame mounting.
- Gold-plated contacts.
- The locking strength is 1400N minimum. (GS-ET-19)
- The head orientation can be rotated, allowing 8 different actuator entries.
- Metal actuator entry slot ensures high durability.
- Actuator with rubber bushings alleviates the impact of the actuator entry slot.
- Environmentally-friendly. RoHs directive compliant.
- Double insulation structure. No need for grounding.
- Compact body: 35 × 40 × 146mm
Type
Name
Downloads
HS5L Interlock Switches with Solenoid (2 Contact)

2 Contact with 8 actuator entry slots
Two-contact solenoid interlock switches ideal for use on applications such as food machines and injection molding machines.
Features & Benefits
- Compact body: 35 × 40 × 127mm
- The locking strength is 1400N minimum.
- Spring clamp terminal block prevents loosening of wires due to vibration.
- Gold-plated contacts suitable for small loads.
- Spring lock models (unlocks when the solenoid is energized) and solenoid lock models (locks when solenoid is energized) are available.
- The head orientation can be rotated, allowing 8 different actuator entries.
- Actuators can be used with other HS5 series interlock switches. Spring loaded actuator exclusive for HS5L available.
- LED indicator shows solenoid operation.
- Automatically locks the actuator without power applied to the solenoid.
- After the machine stops, unlocking is completed by the solenoid, providing high safety features.
- Manual unlocking is possible in the event of power failure or maintenance using a manual unlocking key.
- Head removal detection circuitry (spring lock models only).
- The actuator is locked when energized.
- The actuator is unlocked when de-energized.
- Flexible locking function can be achieved, for an application where locking is not required and sudden stopping of a machine must be prevented.
Type
Name
Downloads
HS5L Interlock Switches with Solenoid (4 Contact)

4 Contact with rear unlocking button
Four contact solenoid interlock switches ideal for use on limited mounting spaces such as small doors.
Features & Benefits
- Compact body: 35 × 40 × 127mm
- The locking strength is 1400N minimum.
- Spring clamp terminal block prevents loosening of wires due to vibration.
- Gold-plated contacts suitable for small loads.
- Spring lock models (unlocks when the solenoid is energized) and solenoid lock models (locks when solenoid is energized) are available.
- The head orientation can be rotated, allowing 8 different actuator entries.
- Actuators can be used with other HS5 series interlock switches. Spring loaded actuator exclusive for HS5L available.
- LED indicator shows solenoid operation.
- Automatically locks the actuator without power applied to the solenoid.
- After the machine stops, unlocking is completed by the solenoid, providing high safety features.
- Manual unlocking is possible in the event of power failure or maintenance using a manual unlocking key.
- HeadThe actuator is locked when energized.
- The actuator is unlocked when de-energized.
- Flexible locking function can be achieved, for an application where locking is not required and sudden stopping of a machine must be prevented. removal detection circuitry (spring lock models only).
Type
Name
Downloads
HS6B Interlock Switches

IP67 Degree of Protection
World class compactness with three poles of contacts.
Features & Benefits
- Compact body: 35 × 40 × 127mm
- The locking strength is 1400N minimum.
- Spring clamp terminal block prevents loosening of wires due to vibration.
- Gold-plated contacts suitable for small loads.
- Spring lock models (unlocks when the solenoid is energized) and solenoid lock models (locks when solenoid is energized) are available.
- The head orientation can be rotated, allowing 8 different actuator entries.
- Actuators can be used with other HS5 series interlock switches. Spring loaded actuator exclusive for HS5L available.
- LED indicator shows solenoid operation.
- Automatically locks the actuator without power applied to the solenoid.
- After the machine stops, unlocking is completed by the solenoid, providing high safety features.
- Manual unlocking is possible in the event of power failure or maintenance using a manual unlocking key.
- HeadThe actuator is locked when energized.
- The actuator is unlocked when de-energized.
- Flexible locking function can be achieved, for an application where locking is not required and sudden stopping of a machine must be prevented. removal detection circuitry (spring lock models only).
Type
Name
Downloads
HS6E Interlock Switches with Solenoid

HS6E Subminiture Interlock Switches with Solenoid
Ideal for applications in tight spaces.
Features & Benefits
- Compact body: 75 × 15 × 75mm
- 15-mm-wide, thinnest solenoid interlock switch in the world.
- Reversible mounting and angled cable allow four actuator insertion directions.
- Energy saving. 24V DC, 110mA (solenoid: 100 mA, LED: 10 mA). Can be driven directly by a controller.
- Manual unlocking possible on three sides.
- LED indicator shows solenoid operation
- Automatically locks the actuator without power applied to the solenoid.
- After the machine stops, unlocking is completed by the solenoid.
- Manual unlocking is possible on three sides in the event of power failure or maintenance.
- The actuator is locked when energized.
- The actuator is unlocked when de-energized.
- Flexible locking function can be achieved, for an application where locking is not required and sudden stopping of a machine must be prevented.